HOME
California
- San Francisco County

COMMUNITY CATEGORIES
Class Reunion Announcements
County or City Guides
Religous Organizations
NonProfit Organizations
School Pages
Government Pages
Personal or Family Pages
Local Geneology Sites

CLASSIFIEDS
Items For Sale
Vehicles For Sale
Items Wanted
Properties For Rent or Lease
Homes For Sale by Owner
Homes For Sale by Agent

BUSINESS CATEGORIES
Agriculture and Animals
Arts, Crafts, Antiques
Automobile and Truck Services
Business Opportunities
Children and Child Care
Computers and Internet
Construction and Home Repair
Entertainment and Leisure
Financial and Insurance
Health and Personal Care
Home Services
News and Media
Professional Services
Real Estate Services
Restaurants and Lodging
Retail, Wholesale Mechandisers
Sports and Fitness
Travel and Lodging
Miscellaneous

Items For Sale
  • Mechanical Parts & Fabrication Services>>>Valve Parts

    SQP Series Vane Pump 1372 ERROR: No record of payment. Why did you add a falsified confirmation number?
    Contact admin to correct misunderstanding. 706-335-3841
    No.588 DANSHUIHONG ROAD CIXI CITY NINGBO CHINA
    ningbo
    86-574-87193975
    E-mail: Shawn
    http://www.hislohydraulic.com

    Our specialties:



  • Vane Pump in Series SQP■General DescriptionSQP series intra-vane pump having high pressure and low sound are developed to meet the application of industry. Total 4 series and 34 sizes are available. Intra-vane design enables the pump having high pressure, large capacity, compact size, low sound level and longer service life features, its main technical data have reached to the advanced level of the same product in the world.With complete specifications, reliable performance, reasonable construction and convenient installation and easy maintenance, it is widely used in hydraulic systems for machine-tools pressure, die casting machines, engineering,plastic injection moulding and other machineries.Main characteristics:1.The pump cartridge of SQP can change with that of Vickers series intra-vane pump.2.It can replace the pump cartridge to change displacement.3.Strengthened pump housing design offers a better anti-vibration ability,which effect the remarkable low noise.■  SQP Series Single Pump▲  Model Code1. F3—Viton seals  Omit if not required2. SQP1—Series designation    SQP1—7.5~45ml/r     SQP2—33~67ml/r    SQP3—81~121ml/r     SQP4—138~237ml/r3. 12—Displacement codeSeriesDisplacement codeSQP12  3  4  5  6  7  8  9  10  11  12  14SQP210  12  14  15  17  19  21SQP325  30  32  35  38SQP442  45  50  57  60  66  75Rated capacity in USgpm at 1200rpm and 0.7MPa4. A—SAE4 bolt flange    M—Metric thread     I—Inch thread5. F—Mounting and shaft seal assembly    S—Flange mount and doubles haft seal    Omit for flange mounting with single shaft seal    F—Foot mounting6. 1—Shaft type    1—1Straight keyed(Standard)    86—86 Straight keyed(Heavy duty)    11—Splined(Not available on SQP1)     151—Splined(For SQP1 only)7. A—Outlet positions (Viewed from cover end of pump)    A—Opposite inlet port    B— 90°CCW from inlet    C—Inlet with inlet    D—90°CW from inlet8. R—Rotation (Viewed from shaft end of pump)    R—Right hand for clockwise,omit    L—Left hand for counterclockwise9.10—Design number▲  Technical DataSeries designationCodeGeometric displacementMin.speed (rpm)Using antiwear hydraulic oil or phosphate ester fluidSound levels at 13.8 MPa,26cSt and 50°C  Weight (kg)ml/rin3/rMax.speed (rpm)Max.operating Pressure (MPa)1200 (rpm)1500 (rpm)1800 (rpm)SQP127.50.46600180014626465163100.614130.79 17.55181.016191.167231.408271.679301.8510321.9511362.2012402.441614452.7814SQP210331.98600180017.26364652512392.3814452.7815472.8917553.3619603.6621674.13SQP325814.94600180017.26468693530975.91321016.16351126.83381217.37SQP4421388.41600180017.267707359.5451478.95501629.855718111.056019311.756621212.937523714.461. The max. pressure of using water glycol fluid is the same as antiwear hydraulic oil or phosphate ester fluid and the max. speed is 1200rpm. 2. The max. pressure of using the water-oil emulsions is 13.8MPa and the max. speed is 1200rpm. ▲  Configuration and Installation Dimension(mm)★SQP1 ★SQP2 ★SQP3       ModelABØCDEØGHJLMØNSQP130.122.219.147.61331.814058.7102.132.9101.6SQP235.726.225.452.41638.116069.9120.638.1127SQP342.830.131.858.71650.818077.7125.538.1127 PQSTØVWØXØF×Full thread depthØK×Full thread depth9.515476.2146.114.21741404-3/8-16UNC-2B Deep 19.14-7/16-14UNC-2B Deep 21.69.51828118117.52131624-3/8-16UNC-2B Deep 19.14-1/2-13UNC-2B Deep 23.89.52119118117.52131834-7/16-14UNC-2B Deep 21.64-1/2-13UNC-2B Deep 23.9★SQP4       ■  SQP Series Double Pump ▲  Model Code F3—Viton seals  Omit if not required2. SQP21—Series Series Geometric displacement(ml/r)Shaft endCover endSQP2133~677.5~45SQP3133~6733~67SQP3281~1217.5~45SQP4181~12133~67SQP42138~2377.5~45SQP43138~23733~673. 21—Displacement code-shaft end pumpSeriesDisplacement CodeSQP2*10  12  14  15  17  19  21SQP3*25  30  35  38SQP4*42  45  50  57  60  66  754. 8—Displacement code-cover end pumpSeriesDisplacement CodeSQP*12  3  4  5  6  7  8  9  10  11  12  14SQP*210  12  14  15  17  19  21SQP*325  30  32  35  385. A—SAE4 bolt flange    M—Metric thread     I—Inch thread6. F—Mounting and shaft seal assembly    S—Flange mount and doubles haft seal    Omit for flange mounting with single shaft seal    F—Foot mounting7. 1—Shaft type    1—Straight keyed(Standard)    86—Straight keyed(Heavy duty)    11—Splined8. AA—Outlet port positions (Viewed from cover end of pump)Outlet positions (All series except SQP43)With No.1 outlet opposite inletAANo.2 outlet 135°CCW from inletABNo.2 outlet 45°CCW from inletACNo.2 outlet 45°CW from inletADNo.2 outlet 135°CW from inletWith No.1 outlet 90°CCW from inletBANo.2 outlet 135°CCW from inletBBNo.2 outlet 45°CCW from inletBCNo.2 outlet 45°CW from inletBDNo.2 outlet 135°CW from inletWith No.1 outlet inline with inletCANo.2 outlet 135°CCW from inletCBNo.2 outlet 45°CCW from inletCCNo.2 outlet 45°CW from inletCDNo.2 outlet 135°CW from inletWith No.1 outlet 90°CW from inletDANo.2 outlet 135°CCW from inletDBNo.2 outlet 45°CCW from inletDCNo.2 outlet 45°CW from inletDDNo.2 outlet 135°CW from inlet  Outlet positions  (Series SQP43) With No.1 outlet opposite inletAANo.2 outlet opposite inletABNo.2 outlet 90°CCW from inletACNo.2 outlet inlet with inletADNo.2 outlet 90°CW from inletWith No.1 outlet 90°CCW from inletBANo.2 outlet opposite inletBBNo.2 outlet 90°CCW from inletBCNo.2 outlet inlet with inletBDNo.2 outlet 90°CW from inletWith No.1 outlet inline with inletCANo.2 outlet opposite inletCBNo.2 outlet 90°CCW from inletCCNo.2 outlet inlet with inletCDNo.2 outlet 90°CW from inletWith No.1 outlet 90°CW from inletDANo.2 outlet opposite inletDBNo.2 outlet 90°CCW from inletDCNo.2 outlet inlet with inletDDNo.2 outlet 90°CW from inlet9. R—Rotation (Viewed from shaft)    R—Right hand for clockwise,omit    L—Left hand for counterclock wise10. 10—Design number▲  Configuration and Installation Dimension(mm)★SQP21 ★SQP31 ★SQP32     ModelABCØDEØFGØHJØKØLMSQP2150.826.21625.452.41279.563.588.919.117.576.2SQP3161.930.11631.858.71279.576.2106.319.117.576.2SQP3261.930.11631.858.71279.576.2106.325.417.580 NPQRSTUØVXYZ88101.638.18126984.118116021322.247.699.5114.438.191.529390.518118021322.247.6109.5114.438.191.531090.518118021326.252.4 Inlet port flange connectionNO.1 outlet port flange connectionNO.2 outlet port flange connection4-1/2-13UNC-2B Deep 23.84-3/8-16UNC-2B Deep 19.14-3/8-16UNC-2B Deep 19.14-5/8-11UNC-2B Deep 28.64-7/16-14UNC-2B Deep 21.64-3/8-16UNC-2B Deep 19.14-5/8-16UNC-2B Deep 28.64-7/16-14UNC-2B Deep 21.64-3/8-16UNC-2B Deep 19.1★SQP4*    See P10 to know the position of SQP43's outletModelABCØDEØFGØHJØKØLMSQP4169.935.72238.169.9152.412.788.9120.719.12376.2SQP4269.935.72238.169.9152.412.788.9120.725.42380SQP4377.835.72238.169.9152.412.7101.6130.231.823101.6 NPQRSTUXYZ119.9119.342.9139.7323115228.627322.247.6135.8119.342.9139.7346115228.627326.252.4148.4133.342.9139.7371115228.627330.158.7 Inlet port flange connectionNO.1 outlet port flange connectionNO.2 outlet port flange connection4-5/8-11UNC-2B Deep 31.84-1/2-13UNC-2B Deep 23.84-3/8-16UNC-2B Deep 19.14-5/8-11UNC-2B Deep 31.84-1/2-13UNC-2B Deep 23.84-3/8-16UNC-2B Deep 19.14-5/8-11UNC-2B Deep 28.64-1/2-13UNC-2B Deep 23.84-7/16-14UNC-2B Deep 20.6■  Shaft Type★  Straight key shaft type                  ModelShaft codeABCØDEF(Key)width×lengthSQP11599.5312.122.22522.2024.5024.404.76×32SQP2SQP211599.5311.122.22522.2024.5024.404.76×3286789.5311.125.37525.35028.3028.106.36×50.8SQP3SQP3*173.29.5311.131.7531.7035.3635.107.94×38.186869.5311.134.934.8738.6038.307.94×54SQP4SQP4*16212.714.2231.75 31.7035.3635.107.94×28.58687.412.714.2238.0738.0542.4042.109.54×50.8★  Splined shaft typeSeriesShaft codeABCDØE               Spline data referenceNumber of teethPitchMajor diameterPitch diameter Minor diameterSuitable formSQP115141.19.5311.13.927.81316/3221.8~21.620.6418.16Side fitSQP2SQP211144.59.5311.13.927.81316/3221.8~21.620.6418.16SQP3SQP3*1158.79.5311.16.3535.11412/2431.2~31.129.6326.99SQP4SQP4*1161.912.714.39.739.61412/2431.2~31.129.6326.99■Installation and Application1.Operating oil①Anti-wear hydraulic oil is recommended. It's viscosity range: 10~100cSt(1.8-13°E),recommended viscosity 24cSt(50℃).②Filtration: the filtration rating shouldn't be lower than 25μm, a filter with filtration rating of 70~150μm should be fitted at inlet port and its rated flow more than twice of that of the pump.③Temperature range: ambient temperature -20~ 70℃; operating temperature 10~ 60℃.④Fire resistance fluid: special seal should be used when using fire resistance fluid; for rated pressure and max. speed of the pump,refer to that in the main performance data table.2.Installation①Foot and frame for pump must be reliable, solid and good in vibration absorbance.②Horizontal mounting is recommended to maintain necessary case fluid level. Concentricity of shafts between pump and motor is important to pump life and should be within Ø0.1mm.Radial or axial load can't be applied on pump shaft and a flexible coupling should be used and rigid linkage not permitted.③To reduce noise and vibration of system caused by trapped air, attachment flange at inlet port, all fittings and pipelines must be strictly sealed.④Before starting the pump, you should check if the inlet and outlet have been correctly connected and the rotation of the pump is in the line with the arrow in the nameplate. To prevent the pump from cavitation caused by the first starting or stopping run for a longer time, air should be bled from the pump delivery line. This may be accomplished by loosening a connection in the delivery line close to the pump. An air bleed valve is available for this purpose. When starting, the pump should be repeatedly jogged without any load. After the pump may normally run, it can be actually primed.⑤Suction lift of pump shouldn't be higher than 500mm.3.Replacing cartridge kitThe cartridge kit design of SQP series vane pumps offers fast and efficient field serviceability.When replacing the cartridge kit, seals inside the pump should be checked to avoid them crimping; when tightening the fastening screws, they should be treated with even force in diagonal direction. 

    Business Location:
    [ Yahoo! Maps ]


  • EDIT THIS LISTING
    Pass Key: